Introduction

Two short codes do most of the work on a polyethylene pipe label: SDR and PN. Get them right and the pipe carries its design pressure safely for decades. Get them wrong and you have either over-paid for wall you did not need or under-specified a line that will fail. Here is what each means and how they connect.

What SDR means

SDR stands for Standard Dimension Ratio. It is simply the ratio of the pipe’s outside diameter to its wall thickness:

SDR = outside diameter ÷ wall thickness

A pipe with SDR 11 has a wall one-eleventh of its diameter. A pipe with SDR 17 has a thinner wall relative to its diameter. The key relationship to remember:

  • Lower SDR = thicker wall = higher pressure rating.
  • Higher SDR = thinner wall = lower pressure rating.

Because SDR is a ratio, it travels with the pipe regardless of size. An SDR 11 pipe has the same proportional wall whether it is 63 mm or 630 mm.

What PN means

PN stands for Pressure Nominal: the maximum continuous operating pressure the pipe is rated for, in bar, at 20°C for water over a 50-year design life. A PN16 pipe is rated for 16 bar.

Quick answer

SDR is the ratio of a PE pipe’s outside diameter to its wall thickness. A lower SDR means a thicker wall and a higher pressure rating (PN). For PE100, common pairings are SDR 17 = PN10, SDR 11 = PN16, and SDR 9 = PN20. You choose the SDR to match your required operating pressure, with a safety margin and an allowance for temperature.

How SDR sets the pressure rating

The design pressure comes from the material’s strength and the pipe’s geometry:

P = 2 × σ / (SDR - 1)

where σ is the design stress, the material’s Minimum Required Strength divided by a safety coefficient (typically 1.25 for water). For PE100, that gives a design stress of 8.0 MPa.

Plug in the SDR and you get the pressure class. The standard pairings for PE100 water pipe:

SDR PE100 pressure class
SDR 26 PN 6.3
SDR 21 PN 8
SDR 17 PN 10
SDR 13.6 PN 12.5
SDR 11 PN 16
SDR 9 PN 20
SDR 7.4 PN 25

Note that the same SDR gives a different PN depending on the material grade. A PE80 pipe at the same SDR carries a lower PN than a PE100 pipe, because PE80 has a lower design stress. PE80 vs PE100: Which to Specify and Why

Temperature derating

The PN values above are for water at 20°C. Polyethylene gets weaker as it warms, so for service above 20°C you apply a derating factor and the pipe’s safe operating pressure drops. For elevated-temperature applications, always check the manufacturer’s derating table rather than using the nominal PN.

Choosing the right SDR

In short: start from your maximum operating pressure (including surge), add the appropriate safety margin, account for temperature, and pick the SDR whose PN meets or exceeds that figure. Installation conditions and the choice between standard PE100 and PE100-RC also feed into the decision. We cover the full selection process separately.

FAQ

Is a lower SDR stronger?
Yes. Lower SDR means a thicker wall relative to diameter, which gives a higher pressure rating.

Does SDR change with pipe diameter?
No. SDR is a ratio, so an SDR 11 pipe keeps the same proportional wall across all diameters. The absolute wall thickness changes, but the rating stays the same.

What is the difference between SDR and PN?
SDR describes the pipe’s geometry (diameter-to-wall ratio); PN is the resulting pressure rating, which also depends on the material grade.

Konti Hidroplast supplies PE100 and PE80 pipes across the full range of SDR classes, from PN6.3 to PN25, in diameters to suit transmission mains and service connections alike. Not sure which SDR your project needs? Contact our technical team.